Non-constrained polyethylene acetabular liner Australia - English - Department of Health (Therapeutic Goods Administration)

non-constrained polyethylene acetabular liner

zimmer biomet pty ltd - 43168 - non-constrained polyethylene acetabular liner - longevity cross-linked polyethylene liners are part of the trilogy acetabular system that is indicated for either cemented or uncemented use in skeletally mature individuals undergoing primary or revision surgery for rehabilitating hips damaged as a result of non-inflammatory degenerative joint disease (nidjd) or its composite diagnoses of osteoarthritis, avascular necrosis, protrusio acetabuli, traumatic arthritis, slipped capital epiphysis, fused hip, fracture of the pelvis, and diastrophic variant.

Pinnacle Marathon Acetabular Liner  - Non-constrained polyethylene acetabular liner Australia - English - Department of Health (Therapeutic Goods Administration)

pinnacle marathon acetabular liner - non-constrained polyethylene acetabular liner

johnson & johnson medical pty ltd t/a depuy synthes - 43168 - non-constrained polyethylene acetabular liner - the pinnacle marathon acetabular liner is constructed from cross-linked uhmwpe and has an inner diameter corresponding to the outer diameter of the femoral head with which it articulates. the outer diameter of the liner corresponds to the inner diameter of the acetabular shell which it snap-locks into. as part of a total hip arthroplasty, the pinnacle marathon acetabular liner is intended to provide increased patient mobility and reduce pain by replacing the damaged hip joint articulation in patients where there is evidence of sufficient sound bone to seat and support the components.

Trilogy Acetabular System Longevity Cross-linked Polyethylene Liner, Standard - Acetabular shell - Non-constrained polyethylene acetabular liner Australia - English - Department of Health (Therapeutic Goods Administration)

trilogy acetabular system longevity cross-linked polyethylene liner, standard - acetabular shell - non-constrained polyethylene acetabular liner

zimmer biomet pty ltd - 43168 - non-constrained polyethylene acetabular liner - the ultra-high molecular-weight polyethylene (uhmwpe) liner is offered in a variety of inner diameters. the device features a neutral (0?) face that provides uniform head coverage. the liner is locked into the shell component once the metal shell has been secured in the acetabulum. a tivanium alloy locking ring, provided preassembled to the shell, secures the liner to the shell. longevity cross-linked polyethylene liners are part of the trilogy acetabular system that is indicated for uncemented use in skeletally mature individuals undergoing primary or revision surgery for rehabilitating hips damaged as a result of noninflammatory degenerative joint disease (nidjd) or its composite diagnoses of osteoarthritis, avascular necrosis, protrusio acetabuli, traumatic arthritis, slipped capital epiphysis, fused hip, fracture of the pelvis, and diastrophic variant.

Trabecular Metal Acetabular Revision System Cemented Constrained Liner Longevity HXLPE  - Constrained polyethylene acetabular liner Australia - English - Department of Health (Therapeutic Goods Administration)

trabecular metal acetabular revision system cemented constrained liner longevity hxlpe - constrained polyethylene acetabular liner

zimmer biomet pty ltd - 44362 - constrained polyethylene acetabular liner - trabecular metal? acetabular revision system cemented constrained liner consists of a liner & reinforcing ring. the highly crosslinked uhmwpe liner fits into the tm acetabular revision system metal shell & articulates with metal femoral heads made by zimmer. the liner?s articular surface has 2 contra-lateral fingers to allow mechanical capture of the femoral head. intended to be cemented into the tm acetabular revision system shell. the reinforcing ring is made from tivanium? ti-6al-4v alloy. the trabecular metal acetabular revision system cemented constrained liner is indicated for use as a component of a total hip prosthesis in primary or revision patients at high risk of hip dislocation due to a history of prior dislocation, bone loss, soft tissue laxity, neuromuscular disease, or intraoperative instability and for whom all other options to constrained acetabular components have been considered.

POLARCUP XLPE Insert  - Non-constrained polyethylene acetabular liner Australia - English - Department of Health (Therapeutic Goods Administration)

polarcup xlpe insert - non-constrained polyethylene acetabular liner

smith & nephew pty ltd - 43168 - non-constrained polyethylene acetabular liner - a sterile, cross-linked ultra-high molecular weight polyethylene (xlpe) acetabular insert which articulates with the femoral ball head. the insert acts as a large head increasing the jump distance and reducing the risk of dislocation and instability in the joint. the liner is non-cemented. polarcup is indicated for advanced degeneration of the hip joint as a result of osteoarthritis, avascular necrosis, posttraumatic arthritis, or rheumatoid arthritis ? femoral neck fracture or proximal fracture of the hip joint ? conditions resulting from previous operations of the hip joint, such as failed total hip prosthesis

Continuum?, Trilogy? IT, Allofit? IT Acetabular Systems Longevity? Highly Crosslinked Polyethylene Elevated Rim Liner  - Non-constrained polyethylene acetabular liner Australia - English - Department of Health (Therapeutic Goods Administration)

continuum?, trilogy? it, allofit? it acetabular systems longevity? highly crosslinked polyethylene elevated rim liner - non-constrained polyethylene acetabular liner

zimmer biomet pty ltd - 43168 - non-constrained polyethylene acetabular liner - the longevity? it elevated liner is a component of the continuum?, trilogy? it, allofit? it acetabular systems. available in 15? elevated rim configuration. approximately 120? of the liner face is elevated in order to provide additional femoral head coverage in one hemisphere. manufactured from longevity?, a highly crosslinked ultra-high molecular weight polyethylene (hxpe). intended for uncemented use. the longevity? it elevated rim liner is indicated for primary or revision surgery in skeletally mature individuals for rehabilitating hips damaged as a result of noninflammatory degenerative joint disease (nidjd) or its composite diagnoses of osteoarthritis, avascular necrosis, protrusio acetabuli, traumatic arthritis, slipped capital epiphysis, fused hip, fracture of the pelvis, and diastrophic variant

Continuum?, Trilogy? IT, Allofit? IT Acetabular Systems Longevity? Highly Crosslinked Polyethylene Neutral Liner  - Non-constrained polyethylene acetabular liner Australia - English - Department of Health (Therapeutic Goods Administration)

continuum?, trilogy? it, allofit? it acetabular systems longevity? highly crosslinked polyethylene neutral liner - non-constrained polyethylene acetabular liner

zimmer biomet pty ltd - 43168 - non-constrained polyethylene acetabular liner - the longevity? it neutral liner is a component of the continuum?, trilogy? it, allofit? it acetabular systems. each liner is identified with a two letter code that corresponds to the mating acetabular shell. manufactured from longevity?, a highly crosslinked ultra-high molecular weight polyethylene (hxpe). the longevity? it neutral liner is indicated for primary or revision surgery in skeletally mature individuals for rehabilitating hips damaged as a result of noninflammatory degenerative joint disease (nidjd) or its composite diagnoses of osteoarthritis, avascular necrosis, protrusio acetabuli, traumatic arthritis, slipped capital epiphysis, fused hip, fracture of the pelvis, and diastrophic variant.

G7 Ceramic Neutral Acetabular liner  - Ceramic acetabular liner Australia - English - Department of Health (Therapeutic Goods Administration)

g7 ceramic neutral acetabular liner - ceramic acetabular liner

zimmer biomet pty ltd - 48055 - ceramic acetabular liner - toughened alumina acetabular liner designed to be inserted into corresponding g7 acetabular shell and provide articulating surface for biolox delta or delta option ceramic modular femoral head. toughened alumina acetabular liner intended to provide a ceramic-on-ceramic option to be used in conjunction with biomet?s g7 acetabular shells, biolox delta ceramic femoral heads and biomet?s femoral stem designs with either a type 1 taper or 12/14 taper, as part of a primary or revision total hip joint replacement.

G7 E1 Freedom constrained acetabular liner - Constrained polyethylene acetabular liner Australia - English - Department of Health (Therapeutic Goods Administration)

g7 e1 freedom constrained acetabular liner - constrained polyethylene acetabular liner

zimmer biomet pty ltd - 44362 - constrained polyethylene acetabular liner - vitamin e infused uhmwpe constrained acetabular liner for use with g7 acetabular shell and freedom constrained femoral head. the pre-assembled constraining ring maximises lever out force of the head and allows easy assembly in situ. the vitamin e acts to maximize polyethylene strength, wear resistance and oxidative resistance. the biomet g7 e1 uhmwpe constrained liner is indicated for use as a component of a total hip prosthesis in primary and revision patients at high risk of dislocation due to a history of prior dislocation, bone loss, joint or soft tissue laxity, neuromuscular disease, or intra-operative instability, and for whom all other options to constrained acetabular components have been considered.

G7 E1 acetabular liner - Non-constrained polyethylene acetabular liner Australia - English - Department of Health (Therapeutic Goods Administration)

g7 e1 acetabular liner - non-constrained polyethylene acetabular liner

zimmer biomet pty ltd - 43168 - non-constrained polyethylene acetabular liner - vitamin e infused polyethylene acetabular liner for use with acetabular shell, with locking mechanism utilizing tightly toleranced tongue and groove fit between shell and liner. the vitamin e acts to maximize polyethylene strength, wear resistance and oxidative resistance. antioxidant infused, highly cross-linked uhmwpe acetabular liner intended for use with the biomet g7 multiple bearing acetabular system in primary or revision cases. the liner must be inserted in the acetabular shell to complete the system. liners may be used with mating components indicated for either cemented or uncemented use.